Scope
Metal Building System Supplier: Steelway Building Systems.
Partition Wall panel: 24GA Through fastened exterior wall panel + (2) layers of rockwool girts cavity fill + 24GA Through fastened liner panel c/w closures and sealant.
Wall panel: 26GA Through fastened exterior wall panel + 9.25” fibreglass batt insulation in the girt cavity fill c/w 1” thermal block to the exterior face of girt + 6 mil poly vapour barrier glued to inside face of girt + 26GA Through fastened liner panel c/w closures and sealant.
Roof: 24GA Standing Seam Roof Panel + 12” fibreglass batt insulation in the purlin cavity c/w 3.5” continuous unfaced fibreglass blanket to top of purlins + Skyliner fabric and banding fastened to the underside of purlins.
Mezzanine: 22GA Through fastened decking c/w perimeter angles.
Eave Height: 32’-6” /25’- 2”
Area: 37,177 SQFT
Slope: 1/2:12